Antibacterial sterilizing block filter & ceramic balls, which combine only mineral materials with high energy level among pure natural metal minerals, maximize the generation of hydroxyl radicals (OH-radicals), which instantaneously kill bacteria only by strengthening water reducing power, Ionized atoms and Degenerative separation of negative charge (-e) and positive charge (+ e) between molecules causes strong resonance (wavelength and wave) phenomenon by rotating rotating electromagnetic wave (π-ray) It makes the human body more vigorous.
Antibacterial sterilizing test
At the water passing test which passes water through the filter at the fast speed of 2m per second at the tap water pressure of 2kg/fcm², the result of the test that has passed the synthetic water containing each strain of escherichia coli, staphylococcus aureus, shigella, salmonella and pseudomonas aeruginosa through the antibacterial sterilizing filter and the result of the test after putting the antibacterial sterilizing ball into the synthetic water of each strain are as follows
The results of tests at Korea Environment & Water Works Institute
[table 1]
Test item | Unit | Results | Remarks | ||
---|---|---|---|---|---|
Synthetic water | Passed water | Removal rate (%) | |||
Escherichia coli | CFU/ml | 3.7 x 10³ | 1.5 x 10² | 95.9 | - |
Staphylococcus aureus | CFU/ml | 5.3 x 10³ | 4.1 x 10² | 92.2 | - |
Pseudomonas aeruginosa | CFU/ml | 2.1 x 10³ | 1.7 x 10² | 91.9 | - |
Salmonella | CFU/ml | 1.9 x 10³ | 1.1 x 10² | 94.2 | - |
Shigella | CFU/ml | 1.4 x 10³ | 88 | 93.7 | - |
[table 2]
Test item | Unit | Results | Remarks | ||
---|---|---|---|---|---|
Synthetic water | 3 hours later(Removal rate) | 6 hours later(Removal rate) | |||
Escherichia coli | CFU/ml | 3 800 | 31(99.2%) | Not detected(100%) | - |
Staphylococcus aureus | CFU/ml | 1 100 | 9(99.2%) | Not detected(100%) | - |
Salmonella | CFU/ml | 1 600 | 15(99.1%) | Not detected(100%) | - |
Shigella | CFU/ml | 1 900 | 16(99.2%) | Not detected(100%) | - |
Pseudomonas aeruginosa | CFU/ml | 2 200 | 21(99.0%) | Not detected(100%) | - |